| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4632 | 21:31-21:31 | 00:00 | (OPS) PFIP light turned red at the top of TCS GUI. Unusual error messages in terminal. | Restarting all of the servers fixed the problem. |
| 4629 | 23:45-23:45 | 00:00 | (OPS) Several "ERROR - device fli0 already in use" messages for all cameras; cameras not functional | Called: Randy
Hit power off all, then power on all, then waited a couple of minutes, then restart pas server, then it worked. |
| 4631 | 21:37-21:37 | 00:00 | (OPS) Incessant "Light guide is in unknown state" errors | |
| 4408 | 05:00-05:05 | 00:05 | while taking long acqcam exposures; changed set temp to 15 from -30 per experiment instructions and PAS server died/defunt | killed -6 PAS server and restarted |
| 4633 | 00:33-00:33 | 00:00 | (OPS) Upon restarting tcs servers dome/shutter communications lost. | We were able to fix the dome communications by moving dome in DAS gui, and if it was safe to open we could try to fix shutter communications that way. |
| 4629 | 00:34-00:34 | 00:00 | (OPS) Legacy dies after "Failed to bind to tcp://192.168.66.31:30800. Already in use?" | Called: Randy
On the third attempt at restarting legacy it seemed to reconnect just fine. Maybe it's just a matter of restarting the server and getting lucky for now. |