| Stack Data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Start | Stop | ee50 | ee80 | Hefi Focus | Mars Focus | Outside Temp | Dome Temp | Truss Temp | Wind Direction | Wind Speed | Stack Type | |
| 07:35 | 08:11 | 0.50 | 0.79 | 965 | 1820 | 19.1 | 19.7 | 19.9 | 171 | 13 | First of Night | |
| ↪ Comments | Focus by eye, initially until could get it into DMI range properly. | |||||||||||
| Problem Reports | ||||
|---|---|---|---|---|
| PR Number | Times | Time Lost | Description | Response |
| 4047 | 04:15-04:45 | 00:30 | Hexapod 5 RTO fault; Jim diagnoses an amplifier problem. Jim called George and they switched it out. | Called: George Damm Amplifier switched out. |
| 4049 | 08:40-08:40 | 00:00 | DMIPOINTS: cound not start Pas client See full text of PR to see what else Jim suggested I try. Also, just wondering, is the APC GUI supposed to show ACQ camera's power status?? | Called: Jim Fowler, also spoke with Matt Shetrone Tried starting PAS and exitting to force ACQ camera to close properly. Waited a good 5 minutes at each step (between starting then exitting, then trying the test. No luck. See full text PR. |
| Ops Comments | none |
|---|
| TO Comments | Lots of radar; T-storm at 11:30 local time. Tracker left at ITF Zero; SAMS ref set, in Operate and closed loop; Temp set to stack temp. |
|---|
| RA Comments | none |
|---|
| Observations | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| File | Target/QID | Exp Start | Exposure | Overhead | Program | Instrument Configuration | Data Type | IQ | Dimm | SkySBrt | Skytrans | SNR | Comments | Charge | |