| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4223 | 03:03-03:03, 05:28-05:28 | 00:00 | Segment 88 and Segment 19 not getting any adjustments from AOA. Green box around the spots but no blue cross hair. | |
| 4217 | 04:47-04:47, 09:46-09:46 | 00:00 | APC beeping | |
| 4173 | 07:22-07:22 | 00:00 | Dome Async error every move in tcs gui, but dome still successfully moves. Switched to DAS Gui so I dont have to deal with the errors. Error in bug report.
| |
| 4226 | 07:24-07:25, 10:12-10:12 | 00:01 | HEFI title red, buttons don't seem to do anything.
Noticed that it happened again while not being used. | Restarted Hefi which fixed it. |
| 1703 | 08:10-08:11 | 00:01 | Removed sensor 51-4 due to ltse. | |
| 08:17-08:17, 09:55-09:59 | 00:04 | Failed to acquire trajectory. Error in bug report as well as more details. No other faults occured with this.
Did not catch uptime for first occurance (was unsure if it was needed).
Uptime for second occurance: 55580.9
| reloaded trajectory which worked. |
| 4228 | 08:25-08:28 | 00:03 | Requested azimuth and direction East are incompatible. Structure was at azimuth before hitting go next. Also recieved a HFC fault when this occured. Details and error are posted in the bug report.
uptime:51888.9
| Reset fault and reload trajectory which worked. |