| Stack Data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Start | Stop | ee50 | ee80 | Hefi Focus | Mars Focus | Outside Temp | Dome Temp | Truss Temp | Wind Direction | Wind Speed | Stack Type | |
| 02:44 | 04:20 | 0.46 | 0.68 | 1065 | +13553 | 8.6 | 9.0 | 9.3 | 96 | 3 | First of Night | |
| ↪ Comments | Temp difference large at start of stacking. ~2C between truss and external. | |||||||||||
| Problem Reports | ||||
|---|---|---|---|---|
| PR Number | Times | Time Lost | Description | Response |
| 1696 | 03:13-03:20 | 00:07 | Following sensors taken out for sudden bad gap readings. I wasn't sure if taking out this many sensors on one segment was ok so I gave Jerry a call. Removing the sensors fixed the problems. Seg 54, sen 1, Grp A, -384.000 Seg 54, sen 2, Grp A, -384.000 Seg 54, sen 3, Grp A, -384.000 Seg 54, sen 4, Grp A, -384.000 Seg 54, sen 5, Grp A, -384.000 Seg 54, sen 6, Grp A, -384.000 | Called: Jerry He said that pulling the 6 sensors was ok and that if that didn't work that I could just remove the segment from the array. |
| 4225 | 05:58-05:58 | 00:00 | HFC fault during cancelling trajectory Y track brake P Switch Fault. Temp ~8C. | Reset fault and sent the next target. |
| 1696 | 04:00-04:00 | 00:00 | Took out 36-6 and 42-3 for LTRSE | |
| 4351 | 08:16-08:18 | 00:02 | Structure Stopped at the wrong position. | Hit abort and resent the target. |
| Ops Comments | none |
|---|
| TO Comments | Clear and calm all night. Wind below 10 mph, temperature steady around 8C. |
|---|
| RA Comments | none |
|---|
| Observations | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| File | Target/QID | Exp Start | Exposure | Overhead | Program | Instrument Configuration | Data Type | IQ | Dimm | SkySBrt | Skytrans | SNR | Comments | Charge | |