Failed to connect to MySQL: Access denied for user ''@'localhost' (using password: NO)

Civil Date
Ephemerides
2015-08-10SunsetSunriseMoon
Set12°18°18°12°RiseRiseSet
01:4702:3903:1110:5211:2412:1609:3922:52
Night Length7:41Sunset Temperature


On-Duty Personnel
Resident AstronomerTelescope OperatorOPS EngineerDay Ops
Sergey Rostopchin / Matthew ShetroneAmy Westfall--


Overlaps
TO OverlapRA Overlap
-Matthew Shetrone

Other PersonnelMatthew Shetrone, Vicki Riley

Guestsnone


Open/Close Log
Open timeOutdoor tempTruss tempClose timeReasonTime open
02:0925.324.810:52engineering08:43
Total Time Open8:43


      
ProgramNight PriorityEngineering
Stack Data
StartStopee50ee80Hefi FocusMars FocusOutside TempDome TempTruss TempWind DirectionWind SpeedStack Type
02:1102:560.450.691020-96924.224.724.914725First of Night
09:4110:500.490.75990175919.219.820.01487First of Night


Problem Reports
PR NumberTimesTime LostDescriptionResponse
406205:00-05:0000:00Over the speakers there's a consistent metal clacking in the dome, and it is wind-driven. Matt went up to the catwalk and found the source, a yellow tie off strap on the lower portion of the tracker platform.
406304:16-04:19, 05:10 - 05:13, 07:04 - 07:0700:09Error message displayed after attempting to abort trajectory when this problem occurs. Many tracks end before their time without any error messages or red lights saying why they ended. When this happens the "on trajectory" light on TCS is still green, and attempting an abort gives the error message displayed in the attached screenshot.
406403:13-03:16, 08:26 - 08:29, 10:15 - 10:1800:09TCS becomes so slow that it is unusable. Takes tens of seconds or more for single commands (like button clicks) to be processed.
405512:20-12:2400:04Moving to stow at slow slew speed caused tracker skew. Happened again this morning, on lower X which is where this problem usually occurs. Left tracker at position where skew occurred.


Ops Commentsnone


TO CommentsMirror team: mirrors behaved well tonight. Nothing to report. At EON dmipoints test quit at point 19 with HFC fault. Left SAMS up and running with reference and temp set to reference temp in case anyone wanted to try again.


RA Commentsnone


Observations
FileTarget/QIDExp StartExposureOverheadProgramInstrument ConfigurationData TypeIQDimmSkySBrtSkytransSNRCommentsCharge