| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4334 | 00:00-00:00 | 00:00 | Steve Steele is not in the list of TOs on the night report. | |
| 4303 | 01:30-01:37 | 00:07 | Got the device offline error for the DMI again, right after stacking and during the temperature/DMI/TT test, i.e. the satellite target after stacking. (01:30 UT) | |
| 4333 | 06:47-07:25 | 00:38 | Whenever we moved to a target the slewing worked just fine, but when it switched to track mode the HFC triggered for what seemed like no reason before it even moved.
Called Jim and found out that this was related to a brake error. Lower X track brake was timing out because it wasn't releasing fast enough. Was unable to even initialize the tracker.
Initializing and slewing through Control Desk worked just fine.
Took recording when slewing to target ended and tracking began, then an HFC fault occurred with no other errors displayed in Eng.Mode fault processing. Recording is called hfcwhentrackingstarts.idf. This HFC trigger when tracking starts has been a recurring error. (Jim is aware of this but had it in original report and kept it as a note here.) | |
| 4335 | 05:00-05:20 | 00:20 | Whenever RA sent target with Dec between 0 and -2 the declination pretty much always showed up as the positive value of the sent declination. Whenever we attempted to move to targets using Go Next it went to the wrong position on sky using the faulty Dec. Azimuth was likewise faulty. | |
| 4336 | 06:24-06:29 | 00:05 | "Failed to set TMCS buffer size" error | |