| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4431 | 01:05-01:50 | 00:45 | Running cal.py caused the pfip circuit breaker to go. Lamp 5b caused the problem. | Called Herman and he is going to come up and fix it. |
| 4434 | 01:13-01:13 | 00:00 | Exiting the TCS gui appears to leave a defunct tcs Gui process running. | Kill -6 all defunct instances of tcs gui and then started tcs gui. |
| 4204 | 02:47-02:51 | 00:04 | Tried to start the pipeline on the TT camera and got a device off line error. ACQ was still working correctly as well as the guider camera.
| Kill -6 the PAS server after turning off images and pipeline on all cameras and restarted it. |
| 4414 | 04:01-04:10 | 00:09 | Track ended early due to a Rho Following Error Fault (Per the tracker status tab). Details in PR. | |