| Stack Data | Did not stack | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Problem Reports | ||||
|---|---|---|---|---|
| PR Number | Times | Time Lost | Description | Response |
| 3937 | 05:00-05:00 | 00:00 | Was unable to turn the power switch on the left cabinet in the LER. The knob was found in the tripped position; had to power off, close cabinet, and power on like normal. Also, as before, large crack in plastic around the knob. | |
| 3939 | 02:00-02:00 | 00:00 | Turning on wavescope and opening HET and Ref shutters yields no visible spots on AOA channel 2. | |
| 1703 | 05:00-05:00 | 00:00 | Removed: 86-3, 8-3 | |
| Ops Comments | none |
|---|
| TO Comments | No stacking due to reported problem 3939. Discovered something interesting: if tracker is initialized through TCS, and then User Mode on ControlDesk is switched to EngMode, it will without fail (I think) trigger the CFD Rto + Y Screw Proximity error. I've been switching to Eng Mode at the end of the night before I turn off the dSPACE, just to manually turn off the contactors, and every time I've done so those particular red lights have triggered on the tracker control panel. So if anyone wanted a reliable way to trigger that, there you go. |
|---|
| RA Comments | none |
|---|
| Observations | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| File | Target/QID | Exp Start | Exposure | Overhead | Program | Instrument Configuration | Data Type | IQ | Dimm | SkySBrt | Skytrans | SNR | Comments | Charge | |