| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4342 | 01:18-01:19 | 00:01 | HEFI timed out (red title bar). May have been caused by Operator (See PR). | |
| 4343 | 01:31-01:31 | 00:00 | During second half of focus test while measuring the stack (when the lamp is taken out of focus) nothing visible on hefi camera. Exposure probably needs to be bumped up in order to see the hefi image. | |
| 4135 | 02:38-02:40 | 00:02 | uptime: 30905.9
HFC fault while going to next target. | Reset the fault and resent the target. |
| 4303 | 06:12-06:23 | 00:11 | DMI would not give a readout due to pas server issues. Tried to guide on ACQ right before this. Details in PR. | Needed to shutdown and restart all servers and the tcs gui. Then needed to reacquire the satellite. |
| 4344 | 06:44-06:46 | 00:02 | TCS went defunct after hitting cancel button under trajectory tab. No other errors presented.
| Restarted TCS server alone and tried to send target again. This solved the problem. |
| 4345 | 10:28-10:48 | 00:20 | Pointing did not seem to be very good. Pointing was not good since the beginning of the night with 1975 coordinates (Details in PR). | Tried to restart dspace and initialize the tracker. |
| 4181 | 10:47-10:48 | 00:01 | SCS error:
UpdateSystemStatus:PPE returned error - 20160118104322 BCD05 - Error Code 01h = Serial Receive error. (seg: 29, act: k) | Acknowledged the error, changed move authority to none then back to sams and it looked to be working fine. |
| 4346 | 11:14-11:20 | 00:06 | uptime: 61834.9
In a trajectory with ~36 mins left the tracker quit tracking as if the track had ended. Tried to send the target again at the current azimuth. It loaded just fine but when I hit go next it did nothing. Details in PR. | |