Failed to connect to MySQL: Access denied for user ''@'localhost' (using password: NO)

Civil Date
Ephemerides
2016-03-17SunsetSunriseMoon
Set12°18°18°12°RiseRiseSet
01:0901:5802:2611:4112:1012:58-10:02
Night Length9:15Sunset Temperature


On-Duty Personnel
Resident AstronomerTelescope OperatorOPS EngineerDay Ops
John CaldwellSteve Steele--


Overlapsnone

Other PersonnelJohn Caldwell

Guestsnone


Open/Close Log
Open timeOutdoor tempTruss tempClose timeReasonTime open
00:3019:.616.210:16twilight09:46
Total Time Open9:46


      
ProgramNight PriorityEngineering
Stack Data
StartStopee50ee80Hefi FocusMars FocusOutside TempDome TempTruss TempWind DirectionWind SpeedStack Type
01:3002:060.520.7611701020515.916.517.010510First of Night


Problem Reports
PR NumberTimesTime LostDescriptionResponse
444110:16-11:0000:44MSG HFC FAULT FAULT. MSG Fault Software (HH) coming from the Tracker Status Tab on the TCS GUI, a TCS Error Count 1, A HFC Fault is lit up on the ControlDesk software as well as Tracker Display Panel light HFC went red on the hardware.I tried to zero on the RPT Card, Master and the Fault Reset, as well as Reset on the Tracker Display Panel, but to no avail.This went on after the closure of the dome. Day crew be aware.
443907:07-07:2000:13A star 41900, 12 Focus Magnitude, +37.4 Dec, 292.5 AZ ended it's trajectory at 07:07 UT. It was only suppose to transit.
444007:26-07:4200:16TCS GUI had an that "Go Next" on the Trajectory Tab to freeze. The dome and the structure went to their correct places, but on the trajectory tab, the processes froze on "next". It happened to me twice 09:18 -9:26 UT.I killed all the processes with "kill -6" and restart the processes and TCS GUI. It solved our problem.


Ops Commentsnone


TO CommentsBeautiful night for observing, not to cold, not to windy.


RA Commentslrs duskflats lrs cals acam stability test


Observations
FileTarget/QIDExp StartExposureOverheadProgramInstrument ConfigurationData TypeIQDimmSkySBrtSkytransSNRCommentsCharge