| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4303 | 05:00-05:00 | 00:00 | Attempting to run DMI from TCS GUI gives a "device is not available" error message, and upon shutting down all systems a lingering non-defunct PAS server remains when chksys is run. | |
| 4304 | 05:57-06:00, 06:40 - 06:42 | 00:05 | Received error message "Failed to adjust trajectory to compensate for the current tracker position." Was unable to Go Next until I figured to move the tracker to the center on the presets menu. (Assuming many different movements would have sufficed.) | |
| 4305 | 05:00-05:00 | 00:00 | Buttons to Start/Activate Loop are consistently grayed out on ACQ camera and guide probe cameras. Unable to guide. | |
| 4306 | 08:47-08:53 | 00:06 | Upon starting TCS GUI after a fresh start of all systems, got a series of X_force_state_event() messages in the Command Status window, all of which were in red. (X=Guider1, Guider2, TT, ACQ, PV, WFS1, WFS2, CWFS) Tested ACQ Cam and it was inoperable. After a ctrl-c shutdown of all systems from htcs command line a tcs_server remained "alive", not defunct. | |