| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4257 | 02:27-02:30 | 00:03 | Tried to start the pipeline on the ACQ camera and got an error.
{
"__exception_type": 2,
"__exception_string": "Non-existent handler ACQ_StartPipeline called.",
"__exception_file": "include/builtin_handlers.h",
"__exception_line": 218,
"__exception_func": "process",
"__effective_id": 10,
"__original_id": 10,
"__origin": "tcsGuiPasAsyncCommandSender.jove.7675.0246beba7->tcp://192.168.66.31:30700",
"__handler": "ACQ_StartPipeline",
"__async": "true",
"__done": "true",
"__ack": "false",
"__error": "true",
"__data_time": "1447986409.052597061",
"__wire_time": "1447986409.052598231",
"__data": "false",
"__pid": 760
} | |
| 4256 | 02:34-04:17 | 01:43 | Abort commands were not going through, remaining black in Command Status window. Shut down everything and upon trying to bring it back up found that HETDEX project not loading in ControlDesk; required restart of trkengspare computer. | |
| 4252 | 05:54-05:56 | 00:02 | Index time a little over 42800. tcs_server went defunct while idle. | Killed everything and restarted. |
| 4253 | 07:54-07:54, 11:01 - 11:03 | 00:02 | After Start Loop command on GC1, new images stopped appearing in that camera display and image count stopped incrementing. (effectively stopped taking images) 4 cameras -- ACQ, GC1, GC2, and TTC -- were running at the time. Commands for GC1 still turned green in the Command Status window.
11:01: GC1 stopped taking images again after Start Loop button was pressed. Attpempted to fix by stopping Pipeline/Images and starting Pipeline/Images and failed. | |
| 4226 | 05:00-05:00 | 00:00 | HEFI still loses communication after GUI being open and idle for a while. | |
| 4255 | 10:30-10:32 | 00:02 | TCS GUI crashed soon after Probe Assembly tab was being examined, and right after a WFS2_set_position command was executed from command line. After restoring GUI and trying to execute same command:
syscmd -T -v 'WFS2_set_position(x_ang=-0.09, y_ang=-0.14)'
TCS GUI crashed again.
It seems like we were trying to move to a bad position, because giving it coordinates that worked did not make TCS GUI crash. | |
| 4254 | 12:13-12:15 | 00:02 | Attempting to move to DIRECTV 10 satellite produced following error
Traceback (most recent call last):
File "/opt/het/hetdex/bin/trajectory", line 455, in
tcs.go_next( move_structure=MoveStructure, move_dome=MoveDome )
File "", line 3, in go_next_method
pytcs.error: remote exception: TMCS failed to acquire trajectory.
Checking top and chksys showed nothing odd.
Index time roughly 65600. | Shut down & restarted everything. |