| Stack Data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Start | Stop | ee50 | ee80 | Hefi Focus | Mars Focus | Outside Temp | Dome Temp | Truss Temp | Wind Direction | Wind Speed | Stack Type | |
| 02:40 | 02:58 | 0.41 | 0.62 | 1078 | 9724 | 18.0 | 18.1 | 18.8 | 313 | 7 | First of Night | |
| Problem Reports | ||||
|---|---|---|---|---|
| PR Number | Times | Time Lost | Description | Response |
| 4390 | 00:40-03:15 | 02:35 | The TCS GUI does not work the ACQ Camera correctly,the frame count does not advance. I called two other TO's and the one did not know anything about this. The other was here last night, I left a message for. I then called Mr. Jim Fowler, he said the other TO that was here last night was having problems with it for a couple of days now. It will be switched out Monday. I guess the actual ACQ Camera was bad. | I shut the ACQ Camera down and power cycled in 1/2 an hour and it came on and repaired it for the time being. |
| Ops Comments | none |
|---|
| TO Comments | There were very many clouds, we waited until after 3:00 AM Central Time, but to avail. |
|---|
| RA Comments | none |
|---|
| Observations | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| File | Target/QID | Exp Start | Exposure | Overhead | Program | Instrument Configuration | Data Type | IQ | Dimm | SkySBrt | Skytrans | SNR | Comments | Charge | |