| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4080 | 02:45-02:55 | 00:10 | After a few power blips SCS stated comm failure; Gui shut down and restarted and come up stating SCS comm failure to M7 and M1; | shutdown SCS server and restarted server cleared these issues. |
| 3856 | 01:30-01:40 | 00:10 | HEFI lost comms with Mars; (power blips) | shutdown entire Mars system and restarted resolved this issue |
| 4081 | 05:40-07:18 | 01:38 | moved slew fast to center and then moved slew fast to right in order to start stacking; ERROR occurred and found a Rho soft limit triggered.
triggered at -0.383 and slipped to -0.445 before recovering
| Called: Amy then Jim
Called Jim who walked me through all of the possible ways to recover.
Ultimately had to power cycle both servo cabinets and Dspace rack in the LER and then slowly moving Rho back to center and re-initializing.
|