Failed to connect to MySQL: Access denied for user ''@'localhost' (using password: NO)

Civil Date
Ephemerides
2026-08-20SunsetSunriseMoon
Set12°18°18°12°RiseRiseSet
01:4002:2702:5811:0011:3112:19-06:15
Night Length8:02Sunset Temperature


On-Duty Personnel
Resident AstronomerTelescope OperatorOPS EngineerDay Ops
Zach VanderboschAiden Dillard--


Overlapsnone

Other PersonnelJusten Pautzke

Guestsnone


Open/Close Log
Open timeOutdoor tempTruss tempClose timeReasonTime open
01:3626.725.311:32twilight09:56
Total Time Open9:56


      
ProgramNight PriorityScience
02:58Science
03:25Engineering (hpf)
05:28Science
08:54Idle due to weather (Clouds)
09:20Science
Stack Data
StartStopee50ee80Hefi FocusMars FocusOutside TempDome TempTruss TempWind DirectionWind SpeedStack Type
02:2002:450.500.73-400-134925.425.525.510613First of Night
07:0007:380.650.94-395-57521.622.422.714110Stack/Re-stack
11:2511:320.580.89-190-57523.023.022.93443Post-Observing


Problem Reports
PR NumberTimesTime LostDescriptionResponse
670907:00-07:0000:00Dome Conditioning System Wide Command Failed to Disable SystemDisabled AHUs individually in dome conditioning page and monitored temperatures.
671008:00-08:0800:08HTOPX Showed CALSPEC Standards that Weren't Currently ObservableSelected a different calspec standard to observe.


Ops Commentsnone


TO CommentsKVM1 unresponsive at beginning of night. Power cycled for fix.


RA Commentsnone


Observations
FileTarget/QIDExp StartExposureOverheadProgramInstrument ConfigurationData TypeIQDimmSkySBrtSkytransSNRCommentsCharge
0001UNe Slave Cal00:01426 HPFcal  Yes
virus0000025_01flat_ldls_long00:0215 VIRUScal  Yes
virus0000025_02flat_ldls_long00:0315 VIRUScal  Yes
virus0000025_03flat_ldls_long00:0415 VIRUScal  Yes
virus0000026_01Cd-A00:0615 VIRUScal  Yes
virus0000026_02Cd-A00:0715 VIRUScal  Yes
0002UNe Slave Cal00:08426 HPFcal  Yes
virus0000026_03Cd-A00:0915 VIRUScal  Yes
virus0000027_01Hg00:1015 VIRUScal  Yes
virus0000027_02Hg00:1215 VIRUScal  Yes
virus0000027_03Hg00:1315 VIRUScal  Yes
lrs20000001_01bias00:140 LRS2cal  Yes
virus0000001_01bias00:140 VIRUScal  Yes
lrs20000001_02bias00:150 LRS2cal  Yes
virus0000001_02bias00:150 VIRUScal  Yes
lrs20000001_03bias00:160 LRS2cal  Yes
virus0000001_03bias00:160 VIRUScal  Yes
lrs20000001_04bias00:170 LRS2cal  Yes
virus0000001_04bias00:170 VIRUScal  Yes
lrs20000001_05bias00:180 LRS2cal  Yes
virus0000001_05bias00:180 VIRUScal  Yes
lrs20000001_06bias00:190 LRS2cal  Yes
virus0000001_06bias00:190 VIRUScal  Yes
lrs20000001_07bias00:190 LRS2cal  Yes
virus0000001_07bias00:200 VIRUScal  Yes
lrs20000001_08bias00:200 LRS2cal  Yes
virus0000001_08bias00:210 VIRUScal  Yes
lrs20000001_09bias00:210 LRS2cal  Yes
virus0000001_09bias00:220 VIRUScal  Yes
lrs20000001_10bias00:220 LRS2cal  Yes
virus0000001_10bias00:220 VIRUScal  Yes
lrs20000001_11bias00:230 LRS2cal  Yes
virus0000001_11bias00:230 VIRUScal  Yes
lrs20000002_01dark00:24360 LRS2cal  Yes
virus0000002_01dark00:24360 VIRUScal  Yes
lrs20000002_02dark00:31360 LRS2cal  Yes
virus0000002_02dark00:31360 VIRUScal  Yes
lrs20000002_03dark00:38360 LRS2cal  Yes
virus0000002_03dark00:38360 VIRUScal  Yes
lrs20000003_01skyflat01:457 LRS2cal  Yes
lrs20000004_01skyflat01:4610 LRS2cal  Yes
lrs20000005_01skyflat01:4713 LRS2cal  Yes
lrs20000006_01skyflat01:4816 LRS2cal  Yes
lrs20000007_01skyflat01:4922 LRS2cal  Yes
lrs20000008_01skyflat01:5130 LRS2cal  Yes
virus0000003_01skyflat01:547 VIRUScal  Yes
virus0000004_01skyflat01:5510 VIRUScal  Yes
virus0000005_01skyflat01:5614 VIRUScal  Yes
virus0000006_01skyflat01:5718 VIRUScal  Yes
virus0000007_01skyflat01:5926 VIRUScal  Yes
virus0000008_01parallel02:512000 VIRUSsci  Yes
0003QID 80202:52969.16.8PSU26-3-012HPFsci2.150.9620.350.87132 Yes
0004QID 80203:09969.10.8PSU26-3-012HPFsci1.630.9020.330.91165 Yes
0005LFC Cal03:27106.5 HPFcal  Yes
virus0000009_01parallel03:326963 VIRUSeng  Yes
0006HD_18514403:3374.57.8ENG26-3-006HPFeng1.780.8819.131.03527 Yes
0007HD_18514403:3574.50.8ENG26-3-006HPFeng1.750.9519.151.03557 Yes
0008HD_18514403:3674.50.8ENG26-3-006HPFeng1.640.9219.161.02589 Yes
0009HD_18514403:3874.5-0.2ENG26-3-006HPFeng1.670.9519.181.02610 Yes
0010HD_18514403:4074.50.8ENG26-3-006HPFeng1.351.0019.181.00692 Yes
0011HD_18514403:4274.50.8ENG26-3-006HPFeng1.760.8319.200.94492 Yes
0012HD_18514403:4374.50.8ENG26-3-006HPFeng1.940.7819.240.93456 Yes
0013HD_18514403:4574.5-0.2ENG26-3-006HPFeng2.030.9019.270.92446 Yes
0014HD_18514403:4774.50.8ENG26-3-006HPFeng2.020.8619.320.88424 Yes
0015HD_18514403:4974.50.8ENG26-3-006HPFeng2.170.8819.320.89327 Yes
0016HD_18514403:5174.50.8ENG26-3-006HPFeng2.080.8819.530.90270 Yes
0017HD_18514403:5274.50.8ENG26-3-006HPFeng1.970.9119.561.01528 Yes
0018HD_18514403:5474.5-0.2ENG26-3-006HPFeng2.080.9519.571.03456 Yes
0019HD_18514403:5674.50.8ENG26-3-006HPFeng2.190.9719.611.01479 Yes
0020HD_18514403:5874.50.8ENG26-3-006HPFeng2.081.1419.620.99541 Yes
0021HD_18514403:5974.50.8ENG26-3-006HPFeng2.201.0819.651.00522 Yes
0022HD_18514404:0174.5-0.2ENG26-3-006HPFeng2.071.0919.690.98616 Yes
0023HD_18514404:0374.50.8ENG26-3-006HPFeng1.911.1419.750.96593 Yes
0024HD_18514404:0574.50.8ENG26-3-006HPFeng2.051.1119.800.97560 Yes
0025HD_18514404:0674.50.8ENG26-3-006HPFeng2.031.1019.840.96569 Yes
0026HD_18514404:0874.50.8ENG26-3-006HPFeng2.021.0819.890.95531 Yes
0027HD_18514404:1074.5-0.2ENG26-3-006HPFeng1.981.1219.910.94520 Yes
0028HD_18514404:1274.50.8ENG26-3-006HPFeng2.011.0419.960.91496 Yes
0029HD_18514404:1474.50.8ENG26-3-006HPFeng2.080.9820.040.90467 Yes
0030HD_18514404:1574.50.8ENG26-3-006HPFeng2.190.9520.080.92465 Yes
0031HD_18514404:1774.5-0.2ENG26-3-006HPFeng2.200.9320.100.91433 Yes
0032HD_18514404:1974.50.8ENG26-3-006HPFeng2.320.9120.110.90400 Yes
0033HD_18514404:2174.50.8ENG26-3-006HPFeng2.181.0320.120.90498 Yes
0034HD_18514404:2274.50.8ENG26-3-006HPFeng2.091.1520.130.91469 Yes
0035HD_18514404:2474.50.8ENG26-3-006HPFeng2.220.9220.120.90430 Yes
0036HD_18514404:2674.5-0.2ENG26-3-006HPFeng2.260.8620.110.88405 Yes
0037HD_18514404:2874.50.8ENG26-3-006HPFeng2.000.8920.120.92517 Yes
0038HD_18514404:3074.50.8ENG26-3-006HPFeng2.080.9620.160.90474 Yes
0039HD_18514404:3174.50.8ENG26-3-006HPFeng2.120.8220.160.91442 Yes
0040HD_18514404:3374.5-0.2ENG26-3-006HPFeng2.260.8620.140.89416 Yes
0041HD_18514404:3574.50.8ENG26-3-006HPFeng2.340.9220.130.91439 Yes
0042HD_18514404:3774.50.8ENG26-3-006HPFeng1.990.9320.160.92472 Yes
0043HD_18514404:3874.50.8ENG26-3-006HPFeng2.091.0920.190.92442 Yes
0044HD_18514404:4074.5-0.2ENG26-3-006HPFeng2.171.0120.200.90523 Yes
0045HD_18514404:4274.50.8ENG26-3-006HPFeng1.971.1020.210.92523 Yes
0046HD_18514404:4474.50.8ENG26-3-006HPFeng2.111.0820.220.93496 Yes
0047HD_18514404:4674.50.8ENG26-3-006HPFeng2.121.0220.230.91456 Yes
0048HD_18514404:4774.50.8ENG26-3-006HPFeng2.220.9720.230.91449 Yes
0049HD_18514404:4974.5-0.2ENG26-3-006HPFeng2.221.1120.220.89420 Yes
0050HD_18514404:5174.50.8ENG26-3-006HPFeng2.281.0520.240.87397 Yes
0051HD_18514404:5374.50.8ENG26-3-006HPFeng2.340.9520.240.85400 Yes
0052HD_18514404:5474.50.8ENG26-3-006HPFeng2.441.0920.260.83360 Yes
0053HD_18514404:5674.5-0.2ENG26-3-006HPFeng2.441.2120.250.82350 Yes
0054HD_18514404:5874.50.8ENG26-3-006HPFeng2.431.0320.250.82460 Yes
0055HD_18514405:0074.50.8ENG26-3-006HPFeng1.951.0520.250.88526 Yes
0056HD_18514405:0274.50.8ENG26-3-006HPFeng1.921.1120.280.87524 Yes
0057HD_18514405:0374.50.8ENG26-3-006HPFeng1.911.0220.290.86502 Yes
0058HD_18514405:0574.5-0.2ENG26-3-006HPFeng1.961.0820.320.85508 Yes
0059HD_18514405:0774.50.8ENG26-3-006HPFeng1.911.1720.330.82500 Yes
0060HD_18514405:0974.50.8ENG26-3-006HPFeng1.951.1020.320.80463 Yes
0061HD_18514405:1074.50.8ENG26-3-006HPFeng1.961.0320.320.80482 Yes
0062HD_18514405:1274.5-0.2ENG26-3-006HPFeng1.921.0820.340.79487 Yes
0063HD_18514405:1474.50.8ENG26-3-006HPFeng1.961.0620.360.78475 Yes
0064HD_18514405:1674.50.8ENG26-3-006HPFeng1.920.9320.360.75473 Yes
0065HD_18514405:1874.59.8ENG26-3-006HPFeng1.991.1120.390.75462 Yes
0066LFC Cal05:20106.5 HPFcal  Yes
0067LFC Cal05:25106.5 HPFcal  Yes
0068LFC Cal05:28106.5 HPFcal  Yes
0069HR6744_tell_std05:35330.26.5HPFtelluric1.831.0519.900.86  Yes
virus0000010_01parallel05:462000 VIRUSsci  Yes
0070QID 79905:47969.16.8PSU26-3-012HPFsci1.661.1819.880.8893 Yes
0071QID 79906:04969.10.8PSU26-3-012HPFsci1.780.9720.010.8297 Yes
0072LFC Cal06:22106.5 HPFcal  Yes
virus0000011_01parallel06:301701.8 VIRUSsci  Yes
0073QID 10006:31820.110.3UT26-3-004HPFsci2.110.9720.340.78135Image quality slightly above 2.0". Please check data quality and reject if needed.Yes
0074QID 10006:45820.11.3UT26-3-004HPFsci2.150.9420.500.82140 Yes
virus0000012_01parallel07:431000 VIRUSsci  Yes
0075QID 96007:44969.15.8UT26-3-012HPFsci1.300.7720.300.72350 Yes
0076LFC Cal08:02106.5 HPFcal  Yes
lrs20000009_01FEIGE110_056_E08:14606.0LRS2spec1.480.9721.400.77  Yes
lrs20000010_01FEIGE110_066_E08:181203.0LRS2spec1.310.9120.930.80  Yes
virus0000013_01FEIGE110_034_E08:24604.0VIRUSspec1.260.7921.750.77  Yes
virus0000013_02FEIGE110_034_E08:27602.0VIRUSspec1.220.8321.690.72  Yes
virus0000013_03FEIGE110_034_E08:29601.0VIRUSspec1.251.0121.680.79  Yes
0077LFC Cal08:34106.5 HPFcal  Yes
lrs20000011_01parallel08:34360 LRS2sci  Yes
virus0000014_01QID 83008:343604.0UT26-3-014VIRUSsci1.411.1021.940.70  Yes
0078LFC Cal08:36106.5 HPFcal  Yes
lrs20000011_02parallel08:41360 LRS2sci  Yes
virus0000014_02QID 83008:413601.0UT26-3-014VIRUSsci1.420.9121.800.75  Yes
lrs20000011_03parallel08:48360 LRS2sci  Yes
virus0000014_03QID 83008:483601.0UT26-3-014VIRUSsci1.380.8921.850.68  Yes
lrs20000012_01parallel08:59360 LRS2sci  Yes
virus0000015_01QID 83508:593605.0UT26-3-014VIRUSsci1.400.8221.740.48 Clouds, low transparency during first exposure.No
0079LFC Cal09:00106.5 HPFcal  Yes
0080LFC Cal09:02106.5 HPFcal  Yes
lrs20000012_02parallel09:07360 LRS2sci  Yes
virus0000015_02QID 83509:073602.0UT26-3-014VIRUSsci1.280.8421.680.53  No
lrs20000012_03parallel09:14360 LRS2sci  Yes
virus0000015_03QID 83509:143601.0UT26-3-014VIRUSsci1.260.9221.680.57  No
virus0000016_01parallel09:252041.5 VIRUSsci  Yes
0081QID 78409:26649.65.2UT26-3-008HPFsci1.290.9020.540.67346 Yes
0082QID 78409:37649.61.2UT26-3-008HPFsci1.320.8220.620.80397 Yes
0083QID 78409:49649.61.2UT26-3-008HPFsci1.290.8620.700.86390 Yes
0084LFC Cal10:01106.5 HPFcal  Yes
virus0000017_01parallel10:043020.2 VIRUSsci  Yes
0085QID 76110:05713.64.1UT26-3-001HPFsci1.310.9720.440.6452 Yes
0086QID 76110:17713.61.1UT26-3-001HPFsci1.320.9320.350.7361 Yes
0087QID 76110:30713.61.1UT26-3-001HPFsci1.300.8020.370.7464 Yes
0088QID 76110:43713.60.1UT26-3-001HPFsci1.270.9320.370.7957 Yes
0089QID 93011:01276.97.4UT26-3-012HPFsci1.290.9120.680.83563 Yes
virus0000018_01parallel11:01318.4 VIRUSsci  Yes
0090LFC Cal11:07106.5 HPFcal  Yes
0091LFC Cal11:12106.5 HPFcal  Yes
lrs20000013_01QID 88811:121806.0UT26-3-009LRS2-Bsci1.4721.580.89  P4
0092LFC Cal11:18106.5 HPFcal  Yes
virus0000019_01parallel11:18360 VIRUSsci  Yes
lrs20000014_01QID 88911:183603.0UT26-3-009LRS2-Rsci1.3321.030.84  P4
0093LFC Cal11:21106.5 HPFcal  Yes
lrs20000015_01bias11:260 LRS2cal  Yes
virus0000020_01bias11:260 VIRUScal  Yes
virus0000021_01Cd-A11:3015 ENG26-3-002VIRUScal  Yes
virus0000022_01Hg11:3215 ENG26-3-002VIRUScal  Yes
0094Dark11:46319.5 HPFcal  Yes
0095Quartz FCU11:5774.5 HPFcal  Yes
0096Quartz FCU11:5974.5 HPFcal  Yes
0097Quartz FCU12:0174.5 HPFcal  Yes
0098Quartz FCU12:0374.5 HPFcal  Yes
0099Quartz FCU12:0574.5 HPFcal  Yes
0100Quartz FCU12:0674.5 HPFcal  Yes
0101Quartz FCU12:0874.5 HPFcal  Yes
0102Alpha Bright Cal12:1085.2 HPFcal  Yes
0103Alpha Bright Cal12:1285.2 HPFcal  Yes
0104Alpha Bright Cal12:1485.2 HPFcal  Yes
0105Alpha Bright Cal12:1685.2 HPFcal  Yes
0106LFC FCU12:19106.5 HPFcal  Yes
0107LFC FCU12:21106.5 HPFcal  Yes
0108LFC FCU12:24106.5 HPFcal  Yes
0109LFC FCU12:26106.5 HPFcal  Yes
0110LFC FCU12:28106.5 HPFcal  Yes
0111LFC FCU12:31106.5 HPFcal  Yes
0112LFC Cal12:34106.5 HPFcal  Yes
0113LFC Cal12:36106.5 HPFcal  Yes
0114Etalon Cal12:44159.8 HPFcal  Yes
0115Etalon Cal12:47159.8 HPFcal  Yes
0116Etalon Cal12:50159.8 HPFcal  Yes
0117Etalon Cal12:53159.8 HPFcal  Yes
0118UNe Slave Cal12:57426 HPFcal  Yes
0119UNe Slave Cal13:05426 HPFcal  Yes
0120UNe Slave Cal13:13426 HPFcal  Yes
0121UNe Slave Cal13:20426 HPFcal  Yes
0122UNe Slave Cal13:28426 HPFcal  Yes
lrs20009900_01bias21:590 LRS2cal  Yes
0090LFC Cal21:59106.5 HPFcal  Yes
virus0009900_01flat_Qth22:0020 VIRUScal  Yes
virus0009901_01bias22:010 VIRUScal  Yes
lrs20009901_01flat_ldls_long_B22:0220 LRS2cal  Yes
virus0009902_01dark22:0315 VIRUScal  Yes
lrs20009902_01Cd-A_B22:0429 LRS2cal  Yes
lrs20009903_01FeAr_R22:0615 LRS2cal  Yes
lrs20009904_01Hg_B22:0715 LRS2cal  Yes
0091Dark22:09319.5 HPFcal  Yes
0093LFC Cal22:45106.5 HPFcal  Yes
0094Dark22:47319.5 HPFcal  Yes
0095Quartz FCU22:5474.5 HPFcal  Yes
0096Quartz FCU22:5674.5 HPFcal  Yes
0097Quartz FCU22:5874.5 HPFcal  Yes
0098Quartz FCU22:5974.5 HPFcal  Yes
0099Quartz FCU23:0174.5 HPFcal  Yes
0100Quartz FCU23:0374.5 HPFcal  Yes
0101Quartz FCU23:0574.5 HPFcal  Yes
0102Alpha Bright Cal23:0785.2 HPFcal  Yes
0103Alpha Bright Cal23:0985.2 HPFcal  Yes
0104Alpha Bright Cal23:1185.2 HPFcal  Yes
0105Alpha Bright Cal23:1385.2 HPFcal  Yes
0106LFC FCU23:15106.5 HPFcal  Yes
0107LFC FCU23:18106.5 HPFcal  Yes
0108LFC Cal23:21106.5 HPFcal  Yes
0109LFC Cal23:23106.5 HPFcal  Yes
0110Etalon Cal23:26159.8 HPFcal  Yes
0111UNe Slave Cal23:30426 HPFcal  Yes
lrs20000020_01flat_Qth_R23:3015 LRS2cal  Yes
lrs20000020_02flat_Qth_R23:3115 LRS2cal  Yes
lrs20000020_03flat_Qth_R23:3315 LRS2cal  Yes
lrs20000020_04flat_Qth_R23:3415 LRS2cal  Yes
lrs20000020_05flat_Qth_R23:3515 LRS2cal  Yes
lrs20000021_01flat_ldls_long_B23:3620 LRS2cal  Yes
0112UNe Slave Cal23:37426 HPFcal  Yes
lrs20000021_02flat_ldls_long_B23:3820 LRS2cal  Yes
lrs20000021_03flat_ldls_long_B23:3920 LRS2cal  Yes
lrs20000022_01Cd-A_B23:4029 LRS2cal  Yes
lrs20000022_02Cd-A_B23:4229 LRS2cal  Yes
lrs20000022_03Cd-A_B23:4329 LRS2cal  Yes
0113UNe Slave Cal23:45426 HPFcal  Yes
lrs20000023_01FeAr_R23:4515 LRS2cal  Yes
lrs20000023_02FeAr_R23:4615 LRS2cal  Yes
lrs20000023_03FeAr_R23:4715 LRS2cal  Yes
lrs20000024_01Hg_R23:4920 LRS2cal  Yes
lrs20000024_02Hg_R23:5020 LRS2cal  Yes
lrs20000024_03Hg_R23:5120 LRS2cal  Yes
0114UNe Slave Cal23:53426 HPFcal  Yes
lrs20000025_01Hg_B23:5315 LRS2cal  Yes
lrs20000025_02Hg_B23:5415 LRS2cal  Yes
lrs20000025_03Hg_B23:5515 LRS2cal  Yes