| PR Number | Times | Time Lost | Description | Response |
|---|
| 4358 | 01:52-03:19 | 01:27 | Rho Prof light was persistently orange on ControlDesk Tracker Monitor tab, and TCS errors were consistently indicated on ControlDesk. Clearing errors caused warning/error lights to flash, and the Prof light switched briefly to green before turning orange again. Rho Amp read n05, which indicated fuses had blown. Rho amp was replaced. | |
| 4359 | 03:20-09:00 | 05:40 | Warning lights on all enabled motors. Unable to move in TCS. Jim says he will fill in the rest. | |
| 4312 | 09:17-09:25 | 00:08 | Unceremonious abort-- no errors on TDP, Tracker Status tab, or tracker monitor tab on Control Desk. Caused by tcs_server hangup that was discovered when none of the targets loaded from HTOP. tcs_server using 100% CPU, upon ctrl-c termination of processes tcs_server remained. | |
| 4360 | 09:30-09:30 | 00:00 | Prof. bus error on LX track motor. | |