On-Duty Personnel
Resident AstronomerTelescope OperatorOPS EngineerDay Ops
Matthew ShetroneJusten Pautzke--


Overlapsnone

Other PersonnelJerry Martin

Guestsnone


Open/Close Log
Open timeOutdoor tempTruss tempClose timeReasonTime open
23:5014.612.5179.7Incorrect start or e
Total Time Open0:00


      
ProgramNight PriorityEngineering
01:20Engineering (box pointing)
Stack Data
StartStopee50ee80Hefi FocusMars FocusOutside TempDome TempTruss TempWind DirectionWind SpeedStack Type
00:3602:100.560.85-1840+1156112.913.213.524311First of Night
First of Night


Problem Reports
PR NumberTimesTime LostDescriptionResponse
425723:59-23:0823:09Tried to start CWFS camera pipeline and got an error "Non-existent handler CWFS_StartPipeline" Tried the PV, TT, and ACQ and the only one that did not give this error was the ACQ. { "__exception_type": 2, "__exception_string": "Non-existent handler CWFS_StartPipeline called.", "__exception_file": "include/builtin_handlers.h", "__exception_line": 218, "__exception_func": "process", "__effective_id": 10, "__original_id": 10, "__origin": "tcsGuiPasAsyncCommandSender.jove.4162.03842fd28->tcp://192.168.66.31:30700", "__handler": "CWFS_StartPipeline", "__async": "true", "__done": "true", "__ack": "false", "__error": "true", "__data_time": "1448409544.696914871", "__wire_time": "1448409544.696917508", "__data": "false", "__pid": 27655 }Called: Jim

Had me edit the pasServer.Conf file so that the line with all the cameras was not commented out.
426800:30-01:2500:55Cannot find HEFI lamp light. AOA view shows array so we should be seeing HEFI light. Jerry and Matthew climbed up to the CCAS tower and adjusted the HEFI lamp. New focus on the HEFI is ~ -1630.
422601:59-01:59, 03:29-03:2900:00HEFI title red and buttons dont turn lamp on or off. Died while idle again.Shut down HEFI and MARS system and restart them.
425402:24-02:2800:04TMCS failed to acquire trajectory. This was for GOES 14. See PR for error listing.Resent the trajectory and it worked. (structure did not need to move the second time)
426602:29-02:31, 02:35-02:37, 02:45-03:10, 03:14-03:1600:31ACQ Error calling runPipeline. ACQ not responsive when starting pipeline. Also ACQ only lasting ~12 images before starting to error out.Called: Jim

stopped images and pipeline, stopped the pasServer and then restarted the pasServer. After talking to Jim we let the camera warm up for 20 mins then started pasServer and set the temperature of the ACQ to -5. The ACQ only worked for 20 images at 2 seconds. Temp reading never reached -5 C set point.
413505:28-05:3200:04uptime:41327.9 TCS Error Count: 5 While on track we got a master fault.reset the fault and tried to go to next trajectory.
425205:38-05:4000:02tcs server went defunct while tracking. telescope still tracking...
426911:55-11:5500:00Dome stays at near closed for a long time and doesnt appear to be moving in the C-Cam. See PR for more detail.


Ops Commentsnone


TO Commentsnone


RA CommentsTonight we completed the diagonal Az for the box pointing tests. We also took some twilight PV and CWFS images.


Observations
FileTarget/QIDExp StartExposureOverheadProgramInstrument ConfigurationData TypeIQDimmSkySBrtSkytransSNRCommentsCharge