| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4257 | 23:59-23:08 | 23:09 | Tried to start CWFS camera pipeline and got an error "Non-existent handler CWFS_StartPipeline" Tried the PV, TT, and ACQ and the only one that did not give this error was the ACQ.
{
"__exception_type": 2,
"__exception_string": "Non-existent handler CWFS_StartPipeline called.",
"__exception_file": "include/builtin_handlers.h",
"__exception_line": 218,
"__exception_func": "process",
"__effective_id": 10,
"__original_id": 10,
"__origin": "tcsGuiPasAsyncCommandSender.jove.4162.03842fd28->tcp://192.168.66.31:30700",
"__handler": "CWFS_StartPipeline",
"__async": "true",
"__done": "true",
"__ack": "false",
"__error": "true",
"__data_time": "1448409544.696914871",
"__wire_time": "1448409544.696917508",
"__data": "false",
"__pid": 27655
} | Called: Jim
Had me edit the pasServer.Conf file so that the line with all the cameras was not commented out. |
| 4268 | 00:30-01:25 | 00:55 | Cannot find HEFI lamp light. AOA view shows array so we should be seeing HEFI light.
Jerry and Matthew climbed up to the CCAS tower and adjusted the HEFI lamp. New focus on the HEFI is ~ -1630. | |
| 4226 | 01:59-01:59, 03:29-03:29 | 00:00 | HEFI title red and buttons dont turn lamp on or off. Died while idle again. | Shut down HEFI and MARS system and restart them. |
| 4254 | 02:24-02:28 | 00:04 | TMCS failed to acquire trajectory. This was for GOES 14. See PR for error listing. | Resent the trajectory and it worked. (structure did not need to move the second time) |
| 4266 | 02:29-02:31, 02:35-02:37, 02:45-03:10, 03:14-03:16 | 00:31 | ACQ Error calling runPipeline. ACQ not responsive when starting pipeline. Also ACQ only lasting ~12 images before starting to error out. | Called: Jim
stopped images and pipeline, stopped the pasServer and then restarted the pasServer. After talking to Jim we let the camera warm up for 20 mins then started pasServer and set the temperature of the ACQ to -5. The ACQ only worked for 20 images at 2 seconds. Temp reading never reached -5 C set point. |
| 4135 | 05:28-05:32 | 00:04 | uptime:41327.9
TCS Error Count: 5
While on track we got a master fault. | reset the fault and tried to go to next trajectory. |
| 4252 | 05:38-05:40 | 00:02 | tcs server went defunct while tracking. telescope still tracking... | |
| 4269 | 11:55-11:55 | 00:00 | Dome stays at near closed for a long time and doesnt appear to be moving in the C-Cam. See PR for more detail. | |