| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 1696 | 00:15-00:15 | 00:00 | removed sensors for LTSE | |
| 4363 | 01:20-01:20 | 00:00 | when exiting tcs gui have to log into terminal and manually kill off remaining tcs gui process... every time... | kill -9 command |
| 4064 | 03:28-04:00 | 00:32 | While on targets tcs gui begins to slow down; including the readout time of guiders including acq and guider1, guider2 windows. read out times start to increase to 30-45 seconds between frames. | Called: Randy
Randy came up to view problem and capture core dump file; unable to determine if problem is in pas server or tcs server |
| 4358 | 04:00-10:00 | 06:00 | While on target TT spot floated off cam and was unable to reacquire the spot; acqcam images had large coma; unable to fix image quality. | Called: Jim and George
Tried all repairs, including restarting DSpace, re-initializing, power cycling controldesk and so on... once Jim arrived he determined it was a blown amplifier and fuse on Hexapod 4; called George will be replaced tomorrow. |