| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 4459 | 03:56-03:56, 05:44-05:44, 09:29-09:29 | 00:00 | In the Legacy tab I told the dome to move to the CCAS position and I recieved a comm error. Error in PR. The dome still moved to correct position however. | Sent dome commands through DAS Gui after second occurrence because it was not reliable through the legacy tab. Eventually the gui would not communicate with the dome at all. |
| 4042 | 04:34-04:35 | 00:01 | Got the strange error in the AOA software again. Error in PR. | Hit "ok" till it went away. AOA continued after that normally. |
| 4460 | 04:53-05:44 | 00:51 | While trying to go to a target using htopx and go next the dome threw an error and the trajectory failed. Error in PR.
Tried to send a new target after restarting the legacy server and recieved a "failed to acquire trajectory" error, HFC fault, trq sensor light, limit switch light, and the tracker was skewed. More details in PR. | Called: Jim
Jim helped to clear the torque limit sensor and to clear the skew. |
| 1696 | 05:58-05:58 | 00:00 | Took out sensor 7-4 for LTRSE.
| |
| 4432 | 06:19-06:21 | 00:02 | PAS slowed way down again. Taking minutes to increase frame count on the ACQ camera. | Stopped all pipelines and restarted the pas server. |
| 4462 | 06:45-07:01, 08:29 - 08:33 | 00:20 | HFC fault again in the middle of a track. Error in tcs gui was "MSG Y Following Error Fault." Tracker skewed 30mm. UX and LX not in agreement.
Fixed the Skew and everything tested out fine. See PR for much more detail.
At 08:29 UT
uptime: 52128.0
Got an HFC fault in the middle of the track but no skew. Checked and there is not skew present so I cleared the fault and we went to another target.
More detail in PR for both occurrences. | |
| 4461 | 09:05-09:05 | 00:00 | Index time: ~54330
Tracker started to oscillated in X as far as I could tell by watching the ACQ camera. This occured during tracking. After the event the guide star was outside of the analysis region and no longer tracking. | |