| Problem Reports |
|---|
| PR Number | Times | Time Lost | Description | Response |
|---|
| 1696 | 00:50-00:50 | 00:00 | removed sensors | |
| 4021 | 01:10-01:10 | 00:00 | Louver bank 5 still not opening | |
| 4139 | 04:18-04:30 | 00:12 | trajectory would not load in htcs | shutdown and restarted |
| 4147 | 04:30-05:35 | 01:05 | ACQ cam not properly reading out; see large horizontal streak when mirror inserted and no streak when mirror removed | Called: herman then randy
Randy came up and we power cycled the acq cam and also moved some filters; unknown which action resolved the issue. |
| 4145 | 08:23-08:26 | 00:03 | while trying to read dmi value; error on tcs about pas server; | found pas server had died; shutdown and restarted all servers and tcs |